Description
Product Information
Product Data | |
Product Thickness (nom.) | 5.5 mm |
Product R-Value | Product R-value at 23oC, R0.15 m2.K/W |
Roll Diameter (nom.) | 420 mm |
Roll Weight (nom.) | 7.7 kg |
Roll Size | 1350 mm x 22.25 m (30 m2) |
Reflectance | Reflective: 97% Anti-glare: 88% |
Emittance | Reflective: E0.03 Anti-glare: E0.12 |
Max. Span | 2.4 m |
Assumption and Key
NCC 2019 prescribes different methods to determine Total R-value Calculations for Volume 1 and Volume 2.
The R-values shown are Total R-values for the building element as required by the Energy Provisions of the NCC Volume 2, calculated in accordance with AS/NZS 4859.2 2018 and NZS 4214, as required.
General Requirements
- Fit Kingspan AIR-CELL neatly around doors, windows, and any penetrations, and tape if necessary to prevent air leakage.
- When taping a plastic squeegee or blade must be used to apply appropriate pressure to the tape. Surfaces must be dry and free from dust, oil or grease prior to taping (please refer to brochure ‘Kingspan Insulation Tape’ for further information).
- Leave minimum 100 mm clearance around heat producing flues or light fittings (refer to light fitting manufacturer).
The instructions in this document are guidelines only and should be interpreted with consideration for the specific building design. The installation of Kingspan AIR-CELL should be in conformance with the applicable clauses from AS 3999 and AS/NZS 4200.2 unless otherwise specified.
Kingspan AIR-CELL can be damaged by intense heat above 105° C and contact with sparks and flame from blow torches, welders, cutting tools, etc. must be avoided.
The installer must make due provision for safety when installing Kingspan AIR-CELL in any application.
Product Specifications
Characteristic | Test Method / Standard | Specification | Classification |
Flammability Index | AS 1530.2 | ≤ 5 | Low |
Material Thermal Resistance | ASTM C518 at 23oC | 0.15 m²·K/W | – |
IR Emittance | AS/NZS 4201.5 | Reflective face: 0.03 Anti-Glare Face: 0.12 |
IR Reflective IR Semi Reflective |
IR Emittance | – | – | Category RS |
Burst Strength | AS 3706.4 (CBR) | 0.9 kN | – |
Vapour Control | ASTM E96 | Vapour Permeable 0.300 μg/N.s |
Class 3 |
Water Control | AS/NZS 4201.4 | Pass | Water Barrier |
Moisture Shrinkage | AS/NZS 4201.3 | < 0.5% | – |
Dry Delamination | AS/NZS 4201.1 | Pass | – |
Wet Delamination | AS/NZS 4201.2 | Pass | – |
Surface Water Absorbency | AS/NZS 4201.6 | ≥ 100g/m2 | High |
Corrosion Resistance | AS/NZS 4859.1:2018 App. E | Pass | – |
Electrical Conductivity | AS/NZS 200.1:2017 – c.5.3.1.2 | ≤ 10MΩ | Electrically Conductive |
Environmental Data Table
Aspect | Characteristic |
Recyclability | Waste not recyclable. Roll width to suit most applications to minimise site waste |
Re-usability | Re-usable if removed with care (long term of service expected) |
Water Use | No water used in Kingspan Insulation’s manufacturing process |
Ozone Depleting Substances | None present in the finish product or in Kingspan Insulation’s manufacturing process |
Packaging | Contains approximately 10% recycled product. Packaging is 100% recyclable |
Embodied Energy | 43 MJ/m² approximately |
Condensation
As thermal performance requirements for the building fabric continue to rise, condensation is becoming an increasingly important design consideration for healthy buildings. Ineffective management of
moisture and vapours can potentially lead to indoor health issues and structural defects which require expensive remedial works.
Interstitial condensation (condensation that occurs within the cavities of the building fabric) can go unnoticed for long periods of time and when persistent it promotes the growth of mould, rot in timber, and corrosion of metal framing and fixings. This interstitial condensation can be effectively mitigated by carefully selecting an appropriate building membrane with a suitable water vapour permeance, allowing moisture to harmlessly pass through the structure.