Description
Product Information
Declared Thermal Conductivity (λ-Value) | Insulant | 0.021 W/m.K at 23oC (Insulant thickness ≥ 45 mm) 0.023 W/m.K at 23oC (Insulant thickness 25 – 44 mm) |
Fibre Cement | 0.23 W/m.K at 23oC (Fibre Cement thickness 6 mm) |
|
Product Dimensions | 2400 mm x 1200 mm (2.88 m2) Other dimension available upon enquiry. Minimum order quantities apply. |
|
Nominal Product Thickness (including Fibre Cement Sheet) | 31, 36, 46, 56, 66 ,76, 86, 96 mm | |
Nominal Fibre Cement Sheet Thickness | 6 mm |
A selection of alternative lining boards to create customised finishes and facings is available. Please contact us for more information.

Assumption and Key
NCC 2019 prescribes different methods to determine Total R-value Calculations for Volume 1 and Volume 2.
The R-values shown are Total R-values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/NZS 4859.2 2018 & NZS 4214. Kingspan Kooltherm® products are manufactured, tested and packaged in conformance with AS/NZS 4859.1:2018.
Product Testing
Characteristic | Standard | Result |
Compressive Stress (Insulant) | AS 2498.3 | Typically exceeds 100 kPa at 10% compression |
Water Vapour Resistance | BS EN 12086:1997 / I.S. EN 12086:1998 | > 35 MN·s/g
For the puspose of calculation of condensation risk, the resistivity of the fibre cement sheet component of the product should be taken as 250 MN·s/g·m. |
Fire Performance
Test | Test Method | Result |
Ignitability Flame Spread Heat Release Smoke Release |
AS 1530.3 | Spread of Flame Index: 0 Smoke Development ≤ 3* |
NCC Group Number in accordance with AS 5637.1 |
AS/NZS 3837 / Amdt 1 |
Group 1** |
Average Specific Extinction Area |
AS/NZS 3837 | ≤ 100 m2/kg** |
Fire-resistance test of elements of construction | AS 1530.4*** | -/240/240 (HDPE pipe) |
*Applies only to the Kingspan Kooltherm K10 Insulation board used in the manufacture of this composite insulated fibre cement product.
** Applies only to the compliant fibre cement facing.
*** Testing to AS 1530.4 for the Kingspan Kooltherm K10 performed in accordance with NCC BCA C3.15 Opening for service penetrations using a 120 mm concrete soffit.
** Applies only to the compliant fibre cement facing.
*** Testing to AS 1530.4 for the Kingspan Kooltherm K10 performed in accordance with NCC BCA C3.15 Opening for service penetrations using a 120 mm concrete soffit.
Environmental Data Table
Aspect | Characteristic |
Recyclability | Non-contaminated insulation site waste is recyclable, but there are currently no facilities in Australia to process returned material |
Re-usability | Re-usable if removed with care (long term of service expected) |
Water Use | No water used in Kingspan Insulation’s manufacturing process |
Blowing Agent Global Warming Potential (GWP) | Manufactured with a blowing agent that has low GWP |
Blowing Agent Ozone Depletion Potential (ODP) | Manufactured with a CFC/HCFC-free blowing agent that has zero ODP |
Packaging | Contains 0% recycled product Polythene wrap and EPS skids 100% recyclable |