Description
Product Information
Declared Thermal Conductivity (λ-Value) |
0.021 W/m.K at 23oC (Insulant thickness ≥ 45 mm) 0.023 W/m.K at 23oC (Insulant thickness 25 – 44 mm) |
Emittance (Foil face) | E0.06 |
Product Dimensions | 2400 mm x 1200 mm (2.88 m2) |
Nominal Product Thickness |
25, 30, 40, 50 mm Other thicknesses available upon enquiry. Minimum order quantities apply |
Assumption and Key
NCC 2019 prescribes different methods to determine Total R-value Calculations for Volume 1 and Volume 2. The systems noted on this page are Total R-values for the building element as required by the Energy Provisions of the National Construction Code, calculated in accordance with AS/NZS 4859.2 2018 & NZS 4214. Kingspan Kooltherm® products are manufactured, tested and packaged in conformance with AS/NZS 4859.1:2018
Fire Resistance
Examples shown are suitable for NCC Class 1 & 10a housing and Fire-Resisting Construction Type C walls in NCC Class 2 – 9 buildings. For Fire-Resisting Construction Type A & B walls in NCC Class 2 – 9 buildings a Performance Solution is required. Please contact Kingspan Insulation Technical Services on 1300 247 235 or email technical@kingspaninsulation.com.au for further guidance.
Product Testing
Characteristic | Standard | Result |
Compressive Stress | AS 2498.3 | Typically exceeds 100 kPa at 10% compression |
Water Vapour Resistance | BS EN 12086:1997 / I.S. EN 12086:1998 | > 35 MN·s/g |
Fire Performance
Test | Test Method | Result |
Ignitability Spread of Flame Index Heat Release Smoke Development |
AS 1530.3 | Spread of Flame Index: 0 Smoke Development: ≤ 3 |
Environmental Data Table
Aspect | Characteristic |
Recyclability | Non-contaminated insulation site waste is recyclable, but there are currently no facilities in Australia to process returned material |
Re-usability | Re-usable if removed with care (long term of service expected) |
Water Use | No water used in Kingspan Insulation’s manufacturing process |
Blowing Agent Global Warming Potential (GWP) | Manufactured with a blowing agent that has low GWP |
Blowing Agent Ozone Depletion Potential (ODP) | Manufactured with a CFC/HCFC-free blowing agent that has zero ODP |
Packaging | Contains 0% recycled product Polythene wrap and EPS skids 100% recyclable |